Burners lit on the KeepRite gas furnace in North York after the new inducer motor was installed

Furnace Project, North York

No Heat From a KeepRite Furnace: Inducer Motor Replacement in North York

This KeepRite gas furnace in North York had stopped running. Our technician diagnosed it on site and found the inducer motor had failed. We took out the faulty inducer assembly, put in a new one, set the gas pressure and tested the furnace through full heating cycles before we left.

  • Problem: Gas furnace not operating
  • Equipment: KeepRite G96 two-stage gas furnace
  • Location: North York, Toronto
  • Fix: New inducer motor assembly with adapter harness, gas pressure adjusted
  • Completed: October 2026
Get a Free Estimate

The Diagnosis

A Furnace That Never Got Past the Inducer

The inducer is a small blower inside the furnace. It pulls combustion gases through the furnace and pushes them out the vent, and the furnace won’t light its burners until that draft is proven.

Here’s the original inducer motor still in place, with the front panel off. Our technician checked it and confirmed the motor had failed. That’s why the furnace wasn’t running.

KeepRite gas furnace in a North York basement with the front panel off and the original inducer motor in place
Inducer motor assembly removed from the KeepRite furnace, held in front of the open cabinet

The Removal

Taking Out the Faulty Inducer Assembly

We disconnected the wiring and removed the whole inducer assembly from the cabinet, housing and all. With it out, the vent connection it mounts to was open and ready for the new part.

The Install

New Inducer Motor, Adapter Harness Included

The replacement inducer motor assembly needed an adapter harness to connect properly to the furnace’s existing wiring. We fitted the harness, mounted the new assembly in place of the old one and connected it up.

New inducer motor installed in the KeepRite furnace with its wiring connected
Digital manometer connected to the gas valve to check and adjust the furnace gas pressure

Before We Left

Gas Pressure Set, Then Full Heating Cycles

With the new inducer in, our technician connected a manometer at the gas valve, checked the gas pressure and adjusted it to the right operating spec.

Then we cycled the furnace and watched each step: ignition, inducer operation, burner operation and heat output. Everything worked as it should, and the furnace was back to normal operation before we finished the call.

Project summary: a gas furnace repair in North York, Toronto, completed in October 2026. A KeepRite furnace that was not operating had a failed inducer motor. The inducer assembly was replaced with a new one and an adapter harness, the gas pressure was adjusted to spec, and the furnace was tested for ignition, inducer and burner operation and heating.

Project Photos

Furnace Repairs in North York

We fix gas furnaces for homeowners in North York and the rest of Toronto. See our furnace and AC services in Toronto, read more about our furnace repair service and KeepRite furnace repairs, or go through our KeepRite furnace troubleshooting guide.

Furnace not starting up?

Get a Free Estimate