The shortened BBQ gas line secured along the foundation wall with brackets after the modification

Gas Line Modification, Innisfil

An Overly Long BBQ Gas Line, Cut Down to Size

An Innisfil homeowner asked us to rework the natural gas line that feeds their BBQ. It ran much further along the outside of the house than it needed to. We took out the extra piping, shortened the line to the length they wanted and made the new joints with gas-rated press fittings.

  • Request: Shorten an outdoor BBQ gas line
  • Line: Natural gas supply to an outdoor BBQ
  • Location: Innisfil, Ontario
  • Method: Gas-rated press fittings, no pipe threading
  • Completed: October 2026
Get a Free Estimate

Before

More Pipe Than the BBQ Needed

The original line ran a long way along the exterior of the house before it reached the BBQ connection. It worked, but the extra length served no purpose and made the setup look cluttered.

The homeowner wanted a cleaner, more practical installation, with the piping shortened to a length they chose.

The original BBQ gas line running a long way along the foundation beside the patio, before it was shortened
Side of the house after the excess gas piping was taken off the foundation wall

Step One

Taking Off the Excess Piping

Our technician removed the gas pipe that wasn’t needed and cleared it off the foundation wall. The remaining line was then modified so it could be rejoined at the new, shorter length.

The steel natural gas piping and fittings that stayed in service were kept, so only the extra run came out.

The Connections

Joined With a Press-Fitting System

Instead of cutting threads on the pipe, the new joints were made with a professional ProPress-style press tool and gas-rated press fittings and connectors. The tool squeezes each fitting onto the pipe to form a secure mechanical connection.

Because there’s no threading to do on site, the modification goes faster and the finished joints look neat and uniform.

Technician using a battery press tool to make a press-fitting connection on the gas pipe
Level resting on the new gas pipe to check it runs straight along the foundation

Finishing Work

Lined Up Straight and Bracketed to the Wall

With the connections made, the shortened line was aligned along the foundation and checked with a level so it runs true.

It’s held to the exterior foundation wall with gas piping support brackets and mounting hardware, so it stays firmly in place.

The Result

A Shorter, Tidier Line to the BBQ

The finished gas line is shorter, properly supported and sits neatly along the outside of the house, ending at the connector that runs to the BBQ.

Project summary: an outdoor BBQ natural gas line modification at a home in Innisfil, Ontario, in October 2026. The existing line was longer than necessary, so the excess piping was removed and the line was shortened to the homeowner’s requested length. New connections were made with gas-rated press fittings using a ProPress-style press tool, and the line was aligned and secured to the foundation wall with support brackets.

Finished gas line along the foundation ending at the flexible connector that runs to the BBQ

Outdoor Gas Piping in Innisfil

We install, move and modify natural gas lines for homes in Innisfil, including BBQ connections and other outdoor gas equipment. Learn about our residential gas line installation, our gas fire pit and patio heater service, or everything we offer for heating, cooling and gas work in Innisfil.

Want your BBQ gas line moved, shortened or added?

Get a Free Estimate